Shanghai, China
Business Type:
Manufacturer/Factory
Number of Employees:
22
Year of Establishment:
2009-08-10
OEM/ODM Service
Sample Available
Spanish / French Speaker

Electromagnetic Flowmeter, Flowmeter, Magnetic Flowmeter manufacturer / supplier in China, offering Split-Type Electromagnetic Water Flowmeter (A+E 81F), Non Contact Radar Level Transmitter, 3mm Random Error Radar Level Sensor (A+E 62LB) and so on.

Gold Member Since 2014
Audited Supplier

Split-Type Electromagnetic Water Flowmeter (A+E 81F)

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $400/ Piece
Transport Package: Wooden Case, Carboard Box
Payment Terms: L/C, T/T
Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Corrosive Liquid/Gas
Size: Dn 15-800
Sensor: Tube/Flange
Application: Industrial Production
Type: Electromagnetic Flow Meter

You Might Also Like

Loading...

Basic Info

Model NO.: A+E 81F
Measuring Media: Liquid
Measuring Principle: Electrical Principles
Measurement Object: Closed Pipeline
Certification: ISO
Item: Electromagnetic Flowmeter
Velocity Range: 0.2~8m/S
Electrode: 316L, Hc, Hb, Ti, Ta
Output: 4-20mA DC, Pulse, RS485
Pressure: Max.16 MPa
Media Temperature: Max 180 C
Ambient Temperature: Sensor 80 C, Converter 50 C
Power Supply: 220VAC or 24VDC
Consumption: <8W
Grounding: Made Into Third Electrode
Trademark: AEAD
Origin: Shanghai
HS Code: 9026100000

Product Description

Split-Type Electromagnetic Water Flowmeter (A+E 81F)
Split-Type Electromagnetic Water Flowmeter (A+E 81F)

The operation of an electromagnetic flowmeter or mag meter is based upon Faraday's Law, which states that the voltage induced across any conductor as it moves at right angles through a magnetic field is proportional to the velocity of that conductor.

Features

--Large choice of liner materials suitable for drinking water, wastewater, chemicals and other liquids.
--Suitable for use in custody transfer applications.
--Measurement is independent of the flow profile.
--Abrasion and corrosion-resistant liners available.
--Electric conductivity of medium can be used for detection of product change.
--No additional pressure loss.
--No moveable parts and long working life.
--Two-way measurement system to detect the positive and negative flow.
--Site LCD displays instantaneous flow, accumulative flow, flow rate. 
--Various types provided according to specific conditions.

Specifications

Applicable pipe size: DN 15-800 (1/2'' to 31-1/2'')
Applicable media: liquid with conductivity > 5 uS / cm
Velocity range: 0.2~8 m/s (0.66 to 26.2 ft/s)
Accuracy: 0.5, 1.0 
Processing pressure: 1.0MPa, 1.6MPa, 4.0MPa, 16MPa optional
Processing temperature: -20 to 150°C, according to lining material
Ambient condition: -40 to 80°C, relative humidity <95%
Power supply: AC220V, 50Hz / DC24V
Display: backlight LCD
Operation: 4 light touch buttons
Signal output:
    4-20mA, loading resistance 750Ω,
    pulse, 0-3kHz, 5V,
    RS485

Consumption: <8W
Cable inlet/outlet: M20*1.5
Protection: transducer IP68, converter IP65
Tube material: carbon steel, stainless steel optional
Lining material: PTFE, rubber, polyurethane, F46, Fs optional
Electrode material: stainless steel, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum optional
Grounding: made into a third electrode, same material with electrode

Main performances of the lining materials

Lining material

Main Performance

Applications

Teflon

1.The most steady material in plastics which is resistible to boiling hydrochloric acid, vitriol fortis as well as strong alkali and organic impregnates.       
2.Not be perfect in abrasion resistance.

Strong corrosive mediums such as strong acid and alkali

F46

1.Have the same abrasion resistance with PTFE.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.

1.The same as PTFE.
2.Applicable in mediums of low abrasion.

Neoprene

1.Be of good elasticity, retractility and abrasion resistance.
2.Be resistant to low acid, alkali and salt but not for oxidation mediums.

Water, sewage and slurry, mineral serosity of low abrasion.

Polyurethane

1.Be of good abrasion resistibility.
2.Not be perfect in acid/alkali resistance.
3.Can't be used for water mixed with organic impregnants.

Applicable in mineral serosity, slurry and coal slurry of high abrasion.

 

Main performances of the electrode materials

Electrode material  

Applications

Stainless steel SS316

Applicable in water, sewage and corrosive mediums. Widely used in industries of petrol, chemistry, carbamide, etc.

Hastelloy B(HB)

Having strong resistance to hydrochloric acid of any consistence which is below boiling point. Also resistible against vitriol, phosphate, hydrofluoricacid,organic acid etc which are oxidable acid, alkali and non-oxidable salt.

Hastelloy C(HC)

Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water

Titanium

Applicable in seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid(such as sulphuric acid, hydrochloric acid)corrosion. But if acid contains antioxidant(such as Fe+++,Cu++) is greatly reduce corrosion.

Tantalum

Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all chemical mediums. Except for hydrofluoric acid, oleum and alkali.

Platinum-iridium

Almost be applicable in all chemical mediums except for aqua fortis, ammonium salt.


This electromagnetic flowmeter can be used to measure the volume flow rate of conducting liquid and seriflux in closed pipes, such as pure water, sewage, all kinds of acid-alkali-salt solution, slurry, pulp, paper pulp and food liquids.

Company

AEAD Technology moves to Chinese first free trade zone --Shanghai Pilot Free Trade Zone in Nov. 2014. That is a milestone for the company development to global market. 

AEAD Technology is committed to provide the very best support possible. Our customers have unique service needs, and we offer a variety of service options to support them. For any questions, you will either get the answer or have one of our professionals to contact you within 24 hours.

 
Split-Type Electromagnetic Water Flowmeter (A+E 81F)


How to contact us?
If you are interested in electromagnetic flowmeters, please call our office at +86-(0)21-5869 6328.
Alternatively, you can send us an email or use the contact form which can be found on the contact page of our website.

Send your message to this supplier

*From:
*To:
avatar Mr. Ethan Zong
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now