Shanghai, China
Business Type:
Manufacturer/Factory
Number of Employees:
22
Year of Establishment:
2009-08-10
OEM/ODM Service
Sample Available
Spanish / French Speaker

Milk Flow Meter, Sewage Flow Meter, Magnetic Flow Meter manufacturer / supplier in China, offering Milk Flow Meter, Non Contact Radar Level Transmitter, 3mm Random Error Radar Level Sensor (A+E 62LB) and so on.

Gold Member Since 2014
Audited Supplier

Milk Flow Meter

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $600/ Piece
Port: Shanghai, China
Production Capacity: 5000pieces/Year
Payment Terms: L/C, T/T
Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Corrosive Liquid/Gas
Size: Dn 15-800
Sensor: Tube/Flange
Application: Industrial Production
Type: Electromagnetic Flow Meter

You Might Also Like

Loading...

Basic Info

Model NO.: A+E 81F
Measuring Media: Liquid
Measuring Principle: Electrical Principles
Measurement Object: Closed Pipeline
Certification: ISO
Velocity Range: 0.2~8m/S
Electrode: 316L, Hc, Hb, Ti, Ta
Output: 4-20mA DC, Pulse, RS485
Pressure: Max.16 MPa
Media Temperature: Max 180 C (356 F)
Ambient Temperature: Sensor 80 C(176 F), Converter 50 C(120 F)
Power Supply: 220VAC or 24VDC
Consumption: <8W
Grounding: Made Into The Third Electrode
Trademark: AEAD
Transport Package: Wooden Case, Carboard Box
Origin: Shanghai
HS Code: 90261000

Product Description

Milk flow meter (A+E 81F)

Milk Flow Meter 

Highlights

--Large choice of liner materials suitable for drinking water, wastewater, chemicals and other liquids.
--Suitable for use in custody transfer applications.
--Measurement is independent of the flow profile.
--Abrasion and corrosion-resistant liners available.
--Electric conductivity of medium can be used for detection of product change.
--No additional pressure loss.
--No moveable parts and long working life.
--Two-way measurement system to detect the positive and negative flow.
--Site digital LCD displays instantaneous flow, accumulative flow, flow rate. 
--Various types provided according to specific conditions.
--Change the grounding as the third electrode.
 
Applications
--water and sewage treatment
--industrial chemical fluids
--viscous fluids
--slurries
--process flow control
 
Parameters
ItemMilk flow meter
Applicable pipe sizeDN 15-800 (1/2'' to 31-1/2'')
Applicable medialiquid with conductivity > 5 uS / cm
Velocity range0.2~8 m/s (0.66 to 26.2 ft/s)
Accuracy0.5%FS, 1.0%FS 
Process connectionflange, ANSI / GB / JIS, 1.0MPa, 1.6MPa, 4.0MPa, 16MPa optional
Processing temperature-20 to 150°C, according to lining material
Ambient condition-40 to 80°C, relative humidity <95%
Power supplyAC220V, 50Hz / DC24V / battery
Displaybacklight LCD
Operation4 light touch buttons
Signal output4-20mA, loading resistance 750Ω,
pulse, 0-3kHz, 5V,
RS485
Consumption<8W
Cable inlet/outletM20*1.5
Protectiontransducer IP68, converter IP65
Tube materialcarbon steel, stainless steel optional
Lining materialPTFE, rubber, polyurethane, F46, Fs optional
Electrode materialstainless steel, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum optional
Groundingmade into a third electrode, same material with electrode
Industrieschemical, environmental, metallurgical, pharmaceutical, papermaking, water supply and drainage, etc.

 

Main performances of the lining materials

Lining material

Main Performance

Applications

Teflon

1.The most steady material in plastics which is resistible to boiling hydrochloric acid, vitriol fortis as well as strong alkali and organic impregnates.       
2.Not be perfect in abrasion resistance.

Strong corrosive mediums such as strong acid and alkali

F46

1.Have the same abrasion resistance with PTFE.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.

1.The same as PTFE.
2.Applicable in mediums of low abrasion.

Neoprene

1.Be of good elasticity, retractility and abrasion resistance.
2.Be resistant to low acid, alkali and salt but not for oxidation mediums.

Water, sewage and slurry, mineral serosity of low abrasion.

Polyurethane

1.Be of good abrasion resistibility.
2.Not be perfect in acid/alkali resistance.
3.Can't be used for water mixed with organic impregnants.

Applicable in mineral serosity, slurry and coal slurry of high abrasion.

 

Main performances of the electrode materials

Electrode material  

Applications

Stainless steel SS316

Applicable in water, sewage and corrosive mediums. Widely used in industries of petrol, chemistry, carbamide, etc.

Hastelloy B(HB)

Having strong resistance to hydrochloric acid of any consistence which is below boiling point. Also resistible against vitriol, phosphate, hydrofluoricacid,organic acid etc which are oxidable acid, alkali and non-oxidable salt.

Hastelloy C(HC)

Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water

Titanium

Applicable in seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid(such as sulphuric acid, hydrochloric acid)corrosion. But if acid contains antioxidant(such as Fe+++,Cu++) is greatly reduce corrosion.

Tantalum

Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all chemical mediums. Except for hydrofluoric acid, oleum and alkali.

Platinum-iridium

Almost be applicable in all chemical mediums except for aqua fortis, ammonium salt.

 


If you are interested in chemical industrial sewage flow meter, please call our office at +86-(0)21-5869 6328.
Alternatively, you can send us an email or use the contact form which can be found on the contact page of our website.

Send your message to this supplier

*From:
*To:
avatar Mr. Ethan Zong
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now