Basic Info
  • Model NO.: A+E 80FA
  • Main Application: Water
  • Sensor: Clamp-on/External
  • Type: Ultrasonic Flow Meter
  • Measuring Principle: Acoustics
  • Certification: CE, ISO
  • Sensor Applied Temperature: 0-160 C (32 to 320 F)
  • Maximum Flow Velocity: 10m/S (32ft/S), Bi-Directional
  • Dimensions: 190*150*90mm (71/2"*6"*31/2")
  • Intuitive Flow Meter Menu: 2*10 Backlight LCD
  • Trademark: AEAD
  • Origin: Shanghai, Cn
  • Accuracy: >±1%
  • Size: Dn 15-6000 (1/2" to 336")
  • Application: Water Supply
  • Measuring Media: Liquid
  • Measurement Object: Closed Pipeline
  • Item: Water Flow Meter
  • Heat Quantity Measurement Function: Optional
  • Outputs: RS 485 / 4-20mA / Oct
  • Protection: IP65
  • Communication: Modbus / FUJI
  • Transport Package: Carboard Box
  • HS Code: 90261000
Product Description

Fixed Installation Ultrasonic Water Flow Meter (A+E 80FA)

The 80FA water flow meter is for permanent flow metering applications. Its modularity offers comprehensive configuration options to make the instrument suitable for everything from simple water flow meter measurements to energy flow monitoring, automated process control and product recognition.
The transmitter electronics are housed in a corrosion-resistant, wall mounted enclosure and can be powered by AC or DC power supplies. By offering a wide range of input, output and communication inferfaces such as RS 485, Modbus and relay, the water flow meter can easily be connected to process automation systems.

Water Flow Meter Features

--Real time data transfer
--Intuitive flow meter menu
--Heat measurement function optional
--Easy installation and operation
--Measuring temperature from 0-160 C (32 to 320 F)
--Ex-enclosure provided
--Powed by either AC & DC

Water Flow Meter Specifications
Flow Element

Working power supply: AC220V/DC8~36V
Accuracy: ≤1%
Max. flow velocity: 10m/s
Measuring period: 500ms (2 times per second, and 128 groups of data collected at each cycle )
Display: 10 digits, 2 lines characters displayed on the same screen
Operation: 2*8 keyboard
Signal output:
     1 way isolated Rs485
     1 way isolated Rs485
     1 way OCT
Signal input:
    3 way 4-20mA
    2 way Pt100 resistor
Communication protocol:Modbus protocol, FUJI extension protocol
Installation:External application installation
Protection:Transducer IP 68, mainframe IP 65
Ex-proof:Exd II BT 4

Fixed Installation Ultrasonic Water Flow Meter (A+E 80FA)

Transducer
Fixed Installation Ultrasonic Water Flow Meter (A+E 80FA)


Other Options and Accessories
The water flow meter could be used as a heating meter when equipped with PT100 resistance. 
Fixed Installation Ultrasonic Water Flow Meter (A+E 80FA)
Support
AEAD Technology is committed to providing the very best water flow meter support possible. Our clients have unique service needs, and we offer a variety of service options to support them. For any request, you will either get the answer within 24 hours!
--Telephone troubleshooting and support
--Applications assistance
--Installation assistance
--Extend service contracts.
AEAD Technology provides factory certified water flow meter repairs, calibrations and re-inspection service for AEAD products. For trainings on ultrasonic flow measurement technology, instrumentation and applications, please contact us for the availability and schedules.

Water Flow Meter Model Selection

LetterParametersOptions
A Y: Integrated
F1: Split wall-mounted type      
F2: Split wall-mounted & anti-explosion type    
F3: Split panel-mounting type
M: Module Type
Mainframe type
 
BWorking power supplyA: AC(85-264VAC)D: DC(24V/8-36VDC)
CThermal FunctionN: NoneY: Yes
D Sensor typeB1: Standard S1 type 
B2: Standard M1 type 
B3: Standard L1 type
B4: High-temperature S1H type      
B5: High-temperature M1H type
C1: Standard Plug-in Type
C2: Cement Plug-in Type   
C3: Water Meter Plug-in Type
G1: Standard Sectional type (flange connection)
G2: Sanitary Sectional type (loose connection)
EMeasurement Tube DiameterDN(mm)_____          
FPipeline Material0: Carbon Steel    
1: Stainless Steel         
2: Cast Iron    
3: Fiberglass  
4: PVC      
5: Cement
GNominal Pressure             MPa
HFlow Accumulative UnitM: Cubic Meter          
L: Liter
IThermal Accumulative UnitN: None K Kc (Kilocalorie) G GJ           
B :BTU (Applicable at abroad)
JSignal OutputA: 4-20Ma    
F: Frequency Output  
T: OCT Output
R: Pulse Output         
4: RS485 Output
KSignal InputA: 3 Way 4_20mA Input, 2-way Platinum Input